Locate the refrigerant leak
The technician pressurized the system with nitrogen and applied bubble leak-detection solution. Bubbles at a high-side service port identified the leak location.
Commercial refrigeration • Cleveland, Ohio
A walk-in cooler was low on refrigerant. Eternity traced the leak to a high-side service port, replaced the port and recharged the system. The technician then observed the cooler operating at 34°F and cycling on and off normally.

Diagnosis and repair
The technician pressurized the system with nitrogen and applied bubble leak-detection solution. Bubbles at a high-side service port identified the leak location.
The remaining refrigerant was recovered, the leaking service port was replaced and the system was recharged to the correct refrigerant charge.
The cooler reached 34°F during the service check. The technician allowed it to cycle on and off and confirmed normal operation during that observation.
Operating checks
The technician evaluated the desired box temperature, evaporator temperature difference and corresponding saturated suction temperature, and reviewed condensing conditions against the air temperature around the condenser.
The final check included the cooler’s 34°F box temperature and normal on/off cycling.
Field photographs
Photographs supplied by the technician from this project.


Observed result
After the service-port replacement and refrigerant recharge, the technician confirmed the cooler’s temperature and observed normal cycling during the visit.